
Stake attention in this memory
The image displays a photograph or scan of a document, likely a page from a textbook or technical manual, presented in French. The page contains a technical diagram of an air conditioning system along with explanatory text. The background exhibits some slight blurring and wavy patterns, possibly due to a scan or photograph of a printed page. At the top of the visible area, there is text discussing air conditioning, stating that "integral air conditioning installations ensure not only the temperature, but also a hygrometric degree." It then introduces the diagram: "Figure V.1 represents the schematic diagram of a central air conditioning installation." The main feature is a detailed schematic diagram titled "Figure V.1 Schéma d'installation d'une centrale de conditionnement d'air C.C.A" (Figure V.1 Installation diagram of a central air conditioning unit C.C.A). The diagram illustrates the flow of air in a central air conditioning system: * **"Air neuf" (Fresh air)** enters from the left, passing through a "Filtre" (Filter). * This fresh, filtered air then mixes with **"Air recyclé" (Recycled air)**, which comes from the "Reprise" (Return) line of the system. * The mixed air proceeds through a series of conditioning components: * **3. Batterie de chauffe (primaire)** (Primary heating coil) * **4. Chambre d'humidification** (Humidification chamber) * **1. Batterie de chauffe (secondaire)** (Secondary heating coil) * **2. Batterie froide** (Cooling coil) * After passing through these components, the air becomes **"Air soufflé" (Supplied air)**. * A **"Ventilateur" (Fan)** then propels the "Air soufflé" into a rectangular enclosure labeled **"Salle" (Room)**. * Inside the "Salle," the air is referred to as **"Air repris" (Return air)**. * A portion of the "Air repris" is channeled back as "Air recyclé" to mix with the "Air neuf," completing the air circulation loop within the system. Below the diagram, there are bullet points providing definitions for the different types of air mentioned in the system: * **"L'air neuf"**: Defined as "L'air de provenance de l'extérieur (destiné à être traité ou non)." (Air coming from outside (intended to be treated or not).) * **"L'air soufflé"**: Defined as "L'air traité (ou non) destiné au local." (Treated air (or not) intended for the premises.) * **"L'air repris"**: Defined as "L'air qui ressort du local après l'avoir traversé (en perdant toutes ces qualités)." (Air that leaves the premises after having passed through it (losing all its qualities).) A faint "Activate" watermark is visible in the bottom right corner of the image.
No transactions found



